Features
1. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life.
2. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality.
3. Intelligence high voltage control system with various APR.
4. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose.
5. High standard digital image processing system provides more post-processing and meets clinical needs.
Technical Specifications
Model | QMDR-3200 | QMDR-5000 | QMDR-6500 | QMDR-8000 |
X-ray Generator | ||||
Power Output | 32KW | 50KW | 65KW | 80KW |
Power Input | Standard 380V 3 Phase. Optional 220V or 110V Single Phase Transformer | |||
Frequency | ≥25KHZ | ≥25KHZ | ≥25KHZ | ≥25KHZ |
Current | 10-400mA | 10-630mA | 10-800mA | 10-1000mA |
Voltage | 40kv-150kv | 40kv-150kv | 40kv-150kv | 40kv-150kv |
mAs | 0.1-400mAs | 0.1-630mAs | 0.1-800mAs | 0.1-1000mAs |
Exposure time | 1-6300ms | 1-6300ms | 1-6300ms | 1-6300ms |
APR program | Equipped | Equipped | Equipped | Equipped |
Intelligent protection system | It has self-protection system. It will give an alarm and check fault code | |||
X-Ray Tube | ||||
Anode type | Rotating Anode | Rotating Anode | Rotating Anode | Rotating Anode |
Focal Spot value | 1.0mm /2.0mm | 0.6mm /1.2mm | 0.6mm /1.2mm | 0.6mm /1.2mm |
Maximum voltage | 125KV | 150KV | 150KV | 150KV |
Revolving speed ofanode | 2800rpm | 2800rpm | 2800rpm | 2800rpm |
Inherent filtration | 1.0mmAl | 1.0mmAl | 1.0mmAl | 1.0mmAl |
Anode heat storagecapacity | 150kHU | 300kHU | 300kHU | 300kHU |
Maximum coolingrate of anode | 410W | 750W | 750W | 750W |
Housing heatstorage capacity | 900kJ | 900kJ | 900kJ | 900kJ |
Flat Panel Detector | ||||
Type | Amorphous Silicon | |||
Scintillator | Cesium Iodide | |||
Vision size | 17*17" (43cmx43cm) | |||
Active pixel | 3072 x 3072 | |||
Pixel pitch | 139um | |||
A/D conversion | 16bits | |||
Spatial resolution | 3.6Lp/mm | |||
Acquisition time | ≤1S | |||
Collimator | ||||
Type | Manual Collimator | |||
Max.window | 350mm×350mm (SID=65cm) | |||
Min.window | 50mm×50mm (SID=100cm) | |||
Lamp | 12~24V AC, DC 2A, 1A | |||
Lamp timer | Automatic illumination with timer for lamp(35S) | |||
Inherent filtration | 1.5mmAl | |||
Illuminant | LED | |||
Grid | ||||
Densities | 103 L/INCH | |||
Ratios | 10:1 | |||
Size | 18”×18” | |||
Focal distance | 180 cm | |||
Table | ||||
Type | Radiography Table | |||
Tabletop size | 2200mm×1040mm | |||
load-bearing | ≥150KG | |||
Movement | ||||
1.Tube Stand | ||||
Up-down movement | ≥1100mm | |||
Stand left-rightmovement | ≥1300mm | |||
Rotational angles of stand | +180°~-180° | |||
Rotational angles of tube | 360° | |||
2.Detector Stand | ||||
Up-down movement | ≥1100mm | |||
Workstation | ||||
Monitor | 24’’ LCD | |||
CPU | ≥2.0GHz | |||
Memory | ≥8GB | |||
HDD | ≥500GB | |||
DICOM3.0 | Query for integration with any PACS | |||
Functions | Import/export function | |||
Image info | ||||
Management of patient info | ||||
Post processing | ||||
Measurement etc. | ||||
24’’ LCD | ||||
Measurement etc. | ||||
24’’ LCD |