Features
-It can be widely used in the examination and diagnosis of human limbs, and is suitable for medical institutions such as hospitals, clinics, physical examination centers, ambulances, etc;
-Simple structure, small size, light weight, no environmental restrictions, no need to build a lead shielded darkroom;
-Mobile rack is flexible and convenient, which can meet the requirements of different workstations, and can be used as a bedside shooting in a hospital ward;
-Three exposure control methods: remote control, hand switch, touch screen;
-Fault self-protection, self-diagnosis, high-precision control of tube voltage and tube current;
-It is a DR digital X-ray photography system.
Technical Specifications
General Parameter | ||||
Model: | QMDR-50 | QMDR-53 | QMDR-56 | QMDR-80 |
Output Power | 5kW | 5.3kW | 5.6kW | 8kW |
Rated Voltage | 220~240VAC | 220~240VAC | 220~240VAC | 220VAC ,±10%, 50Hz |
Inverter Frequency | 100kHz±10% | 100kHz±10% | 100kHz±10% | 100kHz±5% |
kV accuracy | ±10% | ±10% | ±10% | ±4% |
mA accuracy | ±10% | ±10% | ±10% | ≤±(5% ) (mA>25mA,ms>5); ≤±(10% +1mA) (mA≤25mA); |
Rotor | Fixed anode | Fixed anode | Fixed anode | Fixed anode |
Exposure Parameter | ||||
kV Range | 40kV-125kV,1kV step | 40kV-125kV,1kV step | 40kV-125kV,1kV step | 40kV-125kV,1kV step |
mA Range | 10-100mA | 10-100mA | 10-100mA | 10-140mA |
ms Range | 1-4000ms | 1-4000ms | 1-4000ms | 2-2000ms |
ms accuracy | ≤±(5%+0.2ms) | ≤±(5%+0.2ms) | ≤±(5%+0.2ms) | ≤±(5%+0.2ms) |
mAs Range | 0.1-200mAs | 0.1-200mAs | 0.1-200mAs | 0.2-100mAs |
mAs accuracy | ≤±(5%+0.2mAs) | ≤±(5%+0.2mAs) | ≤±(5%+0.2mAs) | ≤±(5%+0.2mAs) |
Optional Parameter | ||||
tech.mode | kV-mAs | kV-mAs | kV-mAs | kV-mAs |
kV-mA-ms | kV-mA-ms | kV-mA-ms | kV-mA-ms | |
Communication interface | RS-232 | RS-232 | RS-232 | RS-232 |
Tube Parameter | ||||
Max power | 5.3kW | 5.3kW | 5.6kW | 8kW |
Focal spot | Small:0.6;Large:1.8 | Small:0.6;Large:1.8 | Small:0.6;Large:1.8 | Small:0.6;Large:2 |
Exposure duty cycle | 1:60 | 1:60 | 1:60 | 1:60 |
Maximum current of small filament | 20mA | 20mA | 20mA | 20mA |
Maximum current of big filament | 100mA | 100mA | 100mA | 140mA |
Leakage radiation loading factor | 125kv,0.24mA | 125kv,0.24mA | 125kv,0.24mA | 125kv,0.24mA |
X-ray tube target angle | 15° | 15° | 15° | 15° |
X-ray tube intrinsic filtration | 0.6mmAl | 0.6mmAl | 0.6mmAl | 0.6mmAl |
Monoblock filtration | 1.5mmAl | 1.5mmAl | 1.5mmAl | 1.5mmAl |
Standard Configure
Mobile rack, flat panel detector, computer
Wired Flat panel detector
Detector category: amorphous silicon
Scintillator CsI
Image size 43×43 cm
Pixel matrix: 3072×3072
Pixel pitch 139 μm
A/D conversion 16 Bit
Spatial resolution 3.6
LP/mm drawing time: 1S
Image workstation
Screen size 14.1/15.6
Processor Core Quad
Core
Memory 8G
Hard disk 512G
Graphics card
Trolley
Net weight 20KG
Maximum height: 1710mm
Adjust 645~1710mm